400 €
New never installed but without original packaging and missing the CD-ROM. This model is now discontinued, MSRP 1600 €.
Télémécanique Preventa XUSLBR5A0320.
range of product
Preventa Safety detection
series name
Basic
product or component type
Safety light curtain type 4
device short name
XUSLB
output type
1 auxiliary output solid-state PNP
2 safety outputs OSSD solid-state PNP (NO) (short-circuit protection)
product specific application
For hand protection
minimum object diameter for detection
30 mm
[Sn] nominal sensing distance
8 m with Programming and Diagnostic Module (PDM)
0.3...20 m
height protected
320 mm
number of beams
16
Complementarydetection system
Transmitter-receiver system
response time
23 ms
kit composition
1 arc suppressor set(s)
1 receiver(s)
1 transmitter(s)
1 test rod(s)
2 sets of 2 brackets with fixings
[EAA] effective aperture angle
2.5 ° at 3 m
light source
GaAIAs LED, 880 nm
[Us] rated supply voltage
24 V DC (+/- 20 %)
[Ie] rated operational current
2 A
current consumption
285 mA (transmitter)
450 mA no-load (receiver)
1.8 A with maximum load (receiver)
output current limits
625 mA for safety outputs OSSD
100 mA for auxiliary output
output voltage
24 V
output circuit type
DC
switching capacity in mA
50 mA
local signalling
1 LED (transmitter), function: power supply
4 LEDs (receiver), function: stop, run, interlock, ECS/B Blanking or FB (Floating Blanking)
electrical connection
1 female connector M12 5 pins (transmitter)
1 female connector M12 8 pins (receiver)
function available
Alignment aid by display of each light beam broken accessible by cabling alone
Auto/manual accessible via programming and diagnostic module
Automatic start accessible by cabling alone
Auxiliary output (PNP, status signalling) accessible by cabling alone
Display of operating modes and faults by LED and/or PDM accessible via programming and diagnostic module
LED display of operating modes and faults accessible by cabling alone
Light beam coding (A or B) accessible via programming and diagnostic module
Monitoring of external switching devices (EDM: External Device Monitoring) accessible via programming and diagnostic module
Programming+downloading of conf settings, via programming+diagnostic module(PDM) accessible via programming and diagnostic module
Sensing distance (short, long) accessible via programming and diagnostic module
Test (MTS: Monitoring Test Signal) accessible by cabling alone
marking
CE
material
Casing : aluminium
End caps : 20 % fibre glass impregnated nylon
fixing mode
End brackets
product weight
1.97 kg
Environmentstandards
OSHA 1910-217C
Machinery directive 2006/42/EC
EMC 2004/108/EC
Work equipment directive 2009/104/EC
EN/IEC 61496-2
OSHA 1910-212
EN/IEC 61496-1-2 for type 4 ESPE
ANSI/RIA R15.06
EN/IEC 61496-1
ANSI B11:19-1990
ROHS directive 2002/95/EC
product certifications
TÜV
CSA
UL
safety level
Type 4 conforming to IEC 61496-1-2
Can reach SIL 3 conforming to IEC 61508 (correctly wired)
Can reach category 4 conforming to EN/ISO 13849-1 (correctly wired)
Can reach PL = e conforming to EN/ISO 13849-1 (correctly wired)
safety reliability data
PFH = 4.9E-8 1/h conforming to IEC 61508 (verified in worst case conf: 256 beams, 2 segments, mute), proof test interval = 20 yr
ambient air temperature for operation
-10...55 °C
ambient air temperature for storage
-25...75 °C
relative humidity
0...95 % without condensation
IP degree of protection
IP65
shock resistance
10 gn for 16 ms conforming to IEC 61496-1
vibration resistance
0.35 +/- 0.05 mm (f = 10...55 Hz) conforming to IEC 61496-1.